ChemicalBook # robots.txt generated at http://www.aizhan.com User-agent: * Allow: / Disallow: /manage Sitemap:http://www.flange-guards.com/sitemap.xml flange Safety Shield,flange safety cover,flange guard,flange protective cover,flange guards,flange protector,flange Protection,valve protection cover

Analysis of reaction furnace flange leak accident

In August 10, 2003, the leakage of sulphur recovery refinery unit reactor steam generator cover flange.

(1) the accident:

In August 10, 2003 21:00, the on duty staff found in the inspection of steam generator, reactor cover flange on the part of the light blue flame, and the outer wall over temperature. Maintenance personnel inspection found leaking reactor steam generator.

(2) the accident analysis:

The reaction furnace steam generator tube head leakage, the process gas in the sulfur vapor in air combustion, the flame was blue.

(3) measures:

A) with steam purge protection, prevent the process gas leakage, expand and flame.

B) take on the reaction furnace steam generator 24 hour monitoring, pay close attention to the steam generator in the reaction furnace. Maintenance personnel tight leakage, plastic injection processing, plugging.